Honeywell Differential Pressure Transmitters - STD800
STD800
Honeywell Technology
Part of the SmartLine® family of products, the STD800 is a high performance differential pressure transmitter featuring piezoresistive sensor technology. By combining differential pressure sensing with on chip static and temperature compensation the STD800 offers high accuracy and stability over a wide range of application pressures and temperatures. The SmartLine family is also fully tested and compliant with Experion® PKS providing the highest level of compatibility assurance and integration capabilities. SmartLine easily meets the most demanding application needs for pressure measurement applications.
Select a link under the "item" tab below to order.
Table 1 | Table 2 | Table 3 | Table 4 | Table 5 | Table 6 | Table 7 | Table 8 | Table 9 |
X | X | X | X | X | X | X | XX | X |
Table 1 | Meter Body Selections |
8 _ _ _ _ _ _ |
_ 1 _ _ _ _ _ | b. Fill Fluid |
3 _ _ _ _ _ _ |
E _ _ _ _ _ _ | a. Process Head & Diaphragm Materials | 316L SS |
| |
_ _ _ _ 1 _ _ | e. Vent/Drain Type/ Location | None |
_ 2 _ _ _ _ _ |
_ _ A _ _ _ _ | c. Process Connection | None (1/4" NPTF female thread Std) |
_ _ H _ _ _ _ |
_ _ _ C _ _ _ | d. Bolt/Nuts |
Table 2 | Meter Body & Connection Orientation |
1 | Head/Connection Orientation | High Side Left, Low Side Right / Std Head Orientation |
Table 3 | Agency Approvals |
0 | No Approvals Required |
A | Explosion proof, intrinsically safe, non-incendive, & dustproof |
B | CSA Explosion proof, intrinsically safe, non-incendive, & dustproof |
C | ATEX Explosion proof, intrinsically safe & non-incendive |
D | IECEx Explosion proof, intrinsically safe & non-incendive |
G | NEPSI Explosion proof, intrinsically safe & non-incendive |
Table 4 | Transmitter Electronics Selections |
_ _ 0 |
_ _ A | c. Customer Interface Selections | Yes (Zeo/Span Only) |
|
_ H _ | b. Output/Protocol | HART Protocol |
|
A _ _ | a. Electronic Housing Material & ConnectionType | 1/2 NPT |
Table 1 | Configuration Selections |
1 _ _ | a. App S/W |
_ 1 _ | b. Output Limit, Failsafe & Write Protect Settings | High> 21.0mAdc |
_ 6 _ |
_ _ S | c. General Config. |
Table 2 | Calibration & Accuracy Selection |
A | a.Accuracy & Calibration | Factory Std |
Table 3 | Accessory Selections |
6 _ _ _ |
_ _ A9 | Minifast® 4 pin (M20) (not suitable for X-Proof applications) |
6 _ _ _ |
_ _ A8 | Minifast® 4 pin (1/2 NPT) (not suitable for X-Proof applications) |
6 _ _ _ |
_ _ A7 | M20 316 SS certified conduit plug |
6 _ _ _ |
_ _ A6 | 1/2 NPT 316 SS certified conduit plug |
6 _ _ _ |
_ _ A2 | 1/2 NPT male to 3/4 NPT female 316 SS certified conduit adapter |
6 _ _ _ |
| Unassembled Conduit Plugs & Adapters |
6 _ _ _ |
_ 2 _ _ | Two wired stainless steel tag (up to 4 lines 26 char/line) |
6 _ _ _ |
_ 1 _ _ | One wired stainless steel tag (up to 4 lines 26 char/line) |
6 _ _ _ |
_ 0 _ _ | No customer tag |
6 _ _ _ |
| Customer Tag Type |
|
0 _ _ _ | b. Mounting Bracket | None |
6 _ _ _ |
_ _ A0 | No conduit plugs or adapters required |
Table 2 | Other Certifications & Options (String in sequence comma delimited (XX, XX, XX,...) |
F1 | Calibration Test Report & Certificate of Conformance (F3399) |
15 | Extended warrantly additional 15 years |
04 | Extended warrantly additional 4 years |
03 | Extended warrantly additional 3 years |
02 | Extended warrantly additional 2 years |
01 | Extended warrantly additional 1 year |
OX | Cert clean for O2 or CL2 service per ASTM G93 |
TP | Over-pressure leak test certificate (1.5X MAWP) (F3392) |
FE | FMEDA (SIL 2/3) Certification (FC33337) |
F5 | Certificate of Origin (F0195) |
F3 | Certificate of Conformance (F3391) |
FX | EN10204 Type 3.1 Material Traceability (FC33341) |
MT | Marine (DNV, ABS, BV, KR, LR) (FC33340) |
F7 | NACE MR0175; MR0103; ISO15156 (FC33339) Process wetted & non-wetted parts |
FG | NACE MR0175; MR0103; ISO15156 (FC33338) Process wetted parts only |
| Certifications & Warranty |
Table 3 | Manufacturing Specials |
| Factory |
0 0 0 0 | Factory Identification |