Honeywell ST3000 Honeywell Smart Gauge Pressure Transmitters

Honeywell Smart Gauge Pressure Transmitters
ST3000

Gauge pressure transmitters are used primarily in applications where the normal pressure is greater than normal atmospheric pressure. These devices provide a linear analog output signal in proportion to the pressure. GP transmitters are also used in some level applications where the pressure inside a duct or the level of fluid inside a tank is not compared to atmospheric pressure.

Smart transmitters have the benefit of adjustable measuring span or range within specified limits. These units can be re-ranged in the field or instrument shop with hand-held communication tools and/or pressure standards. To select the appropriate model, determine the pressure range of the media being measured, identify the temperature of the media being measured, understand the corrosive nature of the media, and consider the mounting of the unit for practical installation, calibration and maintenance of the unit.

Select a link under the "item" tab below to order.

Table 1Table 2Table 3Table 4Table 5Table 6
XXXXXXXXXXXXX
Table 1Range
STD130(0-5 to 0-100 PSID)
STD924(0-10 to 0-400”WC)
STD930(0-10 to 0-100 PSID)
STD120(0-1 to 0-400”WC)
Table 2Partial list
Acarbon steel heads, 316L diaphragm (air service only)
E316 SS heads, 316L diaphragm
F316 SS heads, Hastelloy C276 diaphragm
JHastelloy C276 heads and diaphragm
Table 3Fill fluid
1DC200 silicone (standard)
2CTFE inert fill (oxidizing applications)
Table 4Process connection
H½ “FNPT
A¼ “FNPT
Table 5Options
HCHART compatible electronics
SVspecifies side vents on heads, end vents are standard
T3½”NPT Hastelloy C276 football flange 316 ss.bolts, Teflon o-ring
T2½”NPT Hastelloy C276 football flange, CS bolts, Teflon o-ring
S3½”NPT 316 SS football flange and bolts, Teflon o-ring
S2½”NPT 316 SS football flange, CS bolts, Teflon o-ring
CRNACE A286 SS bolts & 304 SS nuts for process heads
SS316 SS bolts and nuts for process heads
TGstainless steel wired on tag
TCtransmitter span configured electronically
CCcustom calibrated span and ID in transmitter memory
LPtransient voltage protection, lightning protection
ZSzero and span adjustments
SMlocal digital meter
FFFoundation Fieldbus communication
ANanalog output only, no communication
DEHoneywell DE protocol (formerly standard, must specify)
F1calibration test report and certificate o conformance
UMHard copy of full user manual
FBflat bracket for wall mounting only
SB316 SS bracket for 2” pipe stand or wall mounting
MBCS bracket for 2” pipe stand or wall mounting
Table 6Approvals
1CFM Explosion Proof & Intrinsically Safe Class 1 Div 1
2JCSA Explosion Proof & Intrinsically Safe Class 1 Div 1
3HATEX approvals see spec sheet for details