Honeywell DPR 180 180mm Strip Chart Recorders


The DPR180 recorder offers the best price/performance in the market today of any 180mm (7 inch) wide chart recorder.
The recorder is able to monitor up to 24 analogue inputs and up to 36 digital inputs.
It produces clear, fully documented charts at any speed, and in different formats, providing the best, most flexible presentation of the process data.
The large, bright display, with fluorescent chart illumination, provides easy viewing of the data and chart. The flexible product configuration in 5 languages makes it easy to set up and use.
The DPR180 is especially suited to match the needs of chemical, pharmaceutical, power generation, metals processing, environmental monitoring, and other applications where the best chart resolution is required.
• 180 mm (7 inch) chart width.
• 0.05% accuracy full scale. Applicable on a wide choice of actuations and ranges.
• Each input span is adjustable within the selected range, with up to 2 ranges per input.
• Universal (T/C, RTD, mV, mA, V), or linear input (mV, mA, V).
• Fast input scanning (20/sec.)
• Fluorescent display of 2 row of 16 digits, with adjustable brightness.
• Roll or fan fold chart with same cassette. Fully documented chart with trace color assign, thin/thick trace, alarm in red tagging, zooming, zoning, trend, tabular, messages.
• Channel groups available.
• I/O capability : up to 24 analogue inputs, up to 36 output relays, up to 36 digital inputs, up to 8 retransmitted signals.
• Advanced math package
• Fully configurable through the front keys, front PC jack or communication link.
• 2 chart speeds configurable from 1 to 5000 mm/h (0.04 to 200 inch/hr).
• Up to 48 customer messages of 50 characters each.
• Firmware upgradable by PC (Flash memory).
• Input calibration traceable per channel, or channel group.
• Up to 2 custom-input characterizations available.
• Up to 48 alarm set points freely assignable on analogue inputs, maths, communication.
• Up to 36 internal output relays assignable on analogue inputs, maths, events, logic inputs.
• Configurable Periodic chart documentation.
• Periodic report.
• Universal power supply : 100 to 240 Vac/dc.
• Up to 8 retransmitting outputs (4 to 20 mA).
• Universal comm. output: ASCII in RS232, 422/485. MODBUS RTU in RS422/485. ETHERNET/MODBUS RTU Interface,
• Metal door/case, IP55 rated
Select a link under the "item" tab below to order.
Table 1 | Table 2 | Table 3 | Table 4 | Table 5 | Table 6 | Table 7 | Table 8 | Table 9 | Table 10 | Table 11 | Table 12 | Table 13 | Table 14 | Table 15 | Table 16 | Table 17 | Table 18 | Table 19 | Table 20 | Table 21 |
X | X | X | X | X | X | X | X | X | XXX | X | XX | X | X | X | X | X | X | X | X | X |
Table 1 | Digital Inputs/Alarms/Analog Outputs-Slot P |
A | 6 Alarm Relay Outputs (Alarm 31 to 36) |
0 | None |
D | 6 Digital Inputs (Digital 31 to 36) |
C | 4 Auxiliary Current Outputs (5 to 8) |
Table 2 | Math |
A | Math Package |
0 | None |
Table 3 | Digital Inputs/Alarms/Analog Outputs-Slot L |
0 | None |
A | 6 Alarm Relay Outputs (Alarm 13 to 18) |
D | 6 Digital Inputs (Digital 13 to 8) |
Table 4 | Digital Inputs/Alarms/Analog Outputs-Slot N |
0 | None |
A | 6 Alarm Relay Outputs (Alarm 25 to 30) |
D | 6 Digital Inputs (Digital 25 to 30) |
C | 4 Auxiliary Current Outputs (1 to 4) |
Table 5 | Future |
0 | None |
Table 6 | Digital Inputs/Alarms/Analog Outputs-Slot M |
0 | None |
A | 6 Alarm Relay Outputs (Alarm 19 to24) |
D | 6 Digital Inputs (Digital 19 to 24) |
Table 7 | Communications |
0 | None |
1 | Universal Communication (ASCII - Modbus) |
2 | Ethernet Interface |
Table 8 | PCMCIA |
0 | None |
A | PCMCIA Interface |
Table 9 | Door and Case |
0 | Grey Door, Glass Window, with Latch, Standard Case |
F | Black Door, Glass Window, with key Lock, Black Case |
E | Black Door, Glass Window, with Latch, Black Case |
3 | Grey Door, Plastic Window, with key Lock, Standard Case |
2 | Grey Door, Plastic Window, with Latch, Standard Case |
1 | Grey Door, Glass Window, with key Lock, Standard Case |
Table 10 | KEY NUMBER |
D18 | DPR 180 Strip Chart Recorder |
Table 11 | Miscellaneous |
0 | None |
0 | None |
A | Test Report (Calibration Certificate) (Note 5) |
B | Certificate of Conformance |
0 | None |
A | Product Configuration (Note 3) |
B | Product Configuration with User Defined Actuation (Note 3) |
U | User Defined Actuation (Note 3) |
0 | None (Future) |
C | CSA Approval/NRTL/C |
Table 12 | Factory Specials |
00 | None |
XX | Special ST # (refer special list) |
Table 13 | Language/Prompts/Manuals |
0 | Product Information on CD |
E | English Manual |
Table 14 | Input Card 1(Slot A) |
0 | None |
L | 4 Linear Inputs (Channel 1 to 4) |
U | 4 Universal Inputs (Channel 1 to 4) |
Table 15 | Input Card 2 (Slot B) |
0 | None |
L | 4 Linear Inputs (Channel 5 to 8) |
U | 4 Universal Inputs (Channel 5 to 8) |
Table 16 | Input Card 3 (Slot C) |
0 | None |
L | 4 Linear Inputs (Channel 9 to 12) |
U | 4 Universal Inputs (Channel 9 to 12) |
Table 17 | Input Card 4 (Slot D) |
U | 4 Universal Inputs (Channel 13 to 16) |
0 | None |
L | 4 Linear Inputs (Channel 13 to 16) |
Table 18 | Input Card 5 (Slot E) |
L | 4 Linear Inputs (Channel 17 to 20) |
U | 4 Universal Inputs (Channel 17 to 20) |
Table 19 | Input Card 6 (Slot F) |
0 | None |
L | 4 Linear Inputs (Channel 21 to 24) |
U | 4 Universal Inputs (Channel 21 to 24) |
Table 20 | Digital Inputs/Alarms/Analog Outputs-Slot J |
0 | None |
A | 6 Alarm Relay Outputs (Alarm 1 to 6) |
D | 6 Digital Inputs (Digital 1 to 6) |
Table 21 | Digital Inputs/Alarms/Analog Outputs-Slot K |
D | 6 Digital Inputs (Digital 7 to 12) |
0 | None |
A | 6 Alarm Relay Outputs (Alarm 7 to 12) |
Technology | Microprocessor-based (32 bits), with non volatile memory. Flash memory for product software upgrade, or specials, via the front jack. |
||
Analogue inputs | No. of inputs | From 4 up to 24 in groups of 4. | |
Input boards | 2 types : 4 linear inputs per board : mV, V, mA 4 universal inputs per board : mV, V, mA, T/C, RTD, Ohms |
||
Signal source | Thermocouple with cold junction compensation, or with remote compensation temperature configurable between 0 to 80ºC (32 to 176ºF) Line resistance up to 1000 Ohms for T/C, mV, mA, V RTD Pt100 Ohms, 3 wire connections, 40 Ohms balanced max. |
||
Basic math functions |
Square root extraction or channel differential are standard. | ||
Burnout | T/C, mV, V (except following ranges) configurable to upscale, downscale or none Volt : -500, 0, 500 mV ; -1, 0, 1V ; -2, 0, 2V; -5, 0, 5V ; 0, 10V ; -10, 0, 10V : Inherent to Zero volt. RTD : inherent upscale ; mA : inherent downscale. |
||
Display | Fluorescent display |
2 rows of 16 digits, 8.5 mm (.33 inch) high, matrix display. Can display 1 or 2 PV values (5 digits) per line, engineering units (5 digits), alarm status, tag name, math, speed, event messages etc. |
|
Brightness | The display brightness is configurable | ||
Record | Chart | 180 mm (7.09") width | |
Traces | Up to 24 traces, configurable in 6 colors, thin or thick traces, plus digital traces | ||
Trace assignment |
Traces are configurable on analogue inputs, math, communication or digital inputs | ||
Scaling | Per input, up to 2 analogue scales can be configured to be printed on the chart, with engineering units, channel reference and tag name. Each input can be configured independently. The scale can be linear, with up to 10 sub-divisions |
||
Print mode | Trend : Up to 24 traces, with periodic chart documentation configurable in time, from 1 minute to 24 hours with date, time, scales, digital PV print-out over traces or on blank paper, with channel reference, digital traces, alarm messages and customer message. Tabular : Tabular print-out configurable in time from 1 to 1440 minutes with channel number, tag name, digital PV value, engineering unit, alarm status. |
||
Zoning | Each input can be scaled between 0 to 100% of the chart (minimum zone = 20%). | ||
Printing group | Up to 2 groups of channels can be defined, with printing selection by : Alarm, logic inputs or keypad |
||
Pen carriage speed |
1.4 second full scale | ||
Chart length | Roll or fan fold chart 35 meters (115 ft) | ||
Chart speed | 1 or 2 chart speed, fully configurable, selected by : Logic input, alarm communication, front key. | ||
Speed setting | Speeds 1 and 2 are configurable from 1 up to 5000 mm/hr (0.04 to 200 in/hr) | ||
Resolution | Chart resolution is 0.19 mm (0.0075") | ||
Product configuration |
Access | The configuration can be accessed using front keys, PC configurator, or ASCII communication with LPCS software. | |
Protection | 2 password levels protect the unit configuration from unauthorized access. Level 1 = limited access, Level 2 = full protection. | ||
Front keyboard | Configurable and alphanumeric keys allow the operator to change the recorder operation | ||
PC configuration | Through the front jack, the unit can be configured from a PC using a Honeywell PC interface. This provides the facility to copy the product configuration, modify, store, download or upload the configuration, access service diagnostics, and also to upgrade the recorder firmware. | ||
Logic inputs (optional) |
Number of inputs | Up to 36 input contacts, organized in groups of 6 contacts per card Dry contacts (5 mA - 5 Vdc) | |
Actions | Change speed 1 to speed 2, tab interval 1 to 2, digital print-out, print message, print inhibit, event traces, print math calculations. Change range, start/stop math operations Change print group, actuate a relay output Up to 20 event traces are configurable in color and position from 0 to 100% of the chart | ||
Alarms | Set points | Up to 48 set points, freely assignable to analogue inputs, math or communication. | |
Alarm type | High, low, change rate low, change rate high, change rate high-low or deviation with configurable alarm occurrence. | ||
Actions | Can trigger a message, print channel in red in alarm, print in alarm, change the range, change the speed/tabular, print digital PV's Start/stop the math, select the print group, actuate a relay output | ||
Relay output (optional) |
Up to 36 internal relays : 2 A, 250 Vac on resistive load. 1 SPST contact output, normally closed contact (NC), configurable to normally open (NO). Configurable alarm relay acknowledgement. |
||
Alarm event | The recorder can be configured to display events such as : 1 alarm, 1 channel in burnout, paper out, battery fail, communication interrupted | ||
Alphanumeric documentation |
Messages | Up to 48 freely assignable messages of 50 characters each Can be printed with or without date and time over the traces, by alarms, logic inputs, communication, when alarm is ON, OFF or ON/OFF. | |
Process Values | Periodic digital print-out at time intervals configurable from 1 minute to 24 hours or through alarms, digital inputs, communication. | ||
Tag name | Each channel can have up to an 8 character name | ||
Chart scales | each can be configured from 0 to 9 subdivisions | ||
Periodic reports | startup time and period configurable Min, Max, average of selected channels or (math computation) are printed in alphanumeric. Report size max. = 20 lines. | ||
User-Defined Actuations |
Up to 50 breakpoints can be used to define a custom range/actuation. Up to 2 ranges can be defined using the PC Configurator. Polynomial characterization available as special. |
||
Mathematic package (optional) |
Many functions are available such as : Basic math, SqRt, Fo, mass flow totalization, energy consumption, averages, timers, min., max., carbon potential, alarm/logic pulse totalization, RH. The calculations are stored during power interruption. |
||
Actions | The results can be recorded as a trace, a tabular print-out, a periodic report, sent to the communication link, or used to generate a current output signal | ||
Communication (optional) |
Protocols | ASCII in RS232, 422/485. MODBUS RTU in RS422/485. ETHERNET/MODBUS RTU Interface, Interface configured with standard IP address and is utilized with 3rd party software that provides TCP/Modbus driver and OPC capability. |
|
PCMCIA (optional) |
Actions | Archiving of PV traces, alarms and events with file names, file size is 24Mbytes max. Logging time selectable from 1 second up to 30 minutes. | |
PC Analysis | TrendManager Pro provides an easy and powerful way to analyze trend, alarm and event files as well as to export them in spreadsheet format (CSV). | ||
Retransmitting signals (optional) |
Current output | Up to 8 signals, 4 to 20 mA dc, can be generated by the recorder (Organized in blocks of 4 output signals) Max. Line impedance = 800 Ohms These can be configured for : analogue traces, math calculations, PV's from the communication link. The zero and span are configurable. | |
Clock timer | Format | Year, month, hour, minute can be set | |
Power interruption | Battery backed (10 years time, 3 years power off) | ||
Accuracy | 10-5 at reference conditions | ||
Power supply | 100 to 230 Vac/dc, (24 Vac/dc on request). Consumption = 100 VA max | ||
Packaging | Weight | 18 Kg max. (38 lbs) | |
Front bezel | 310 x 317 mm (12.2 x 12.5 inches) | ||
Panel cutout | 278 x 278 mm (10.9 x 10.9 inches) | ||
Depth | 320 mm (12.6 inch) including the rear cover | ||
Front protection | IP55 | ||
Lock | Latch, optional key DIN 43832-N | ||
Door | Die cast aluminum : Dark gray or black (optional), door opens to 180º | ||
Mounting | Panel mounting ± 30º from the horizontal | ||
Wiring | Screw terminals : Terminal blocks plug on to the boards at the back of the recorder | ||
Temperature | Ambient | 0 to 50ºC (32 to 132ºF), 0 to 40ºC (32 to 104ºF) for fan fold paper | |
Storage | -40 to 70ºC (-40 to 160ºF) | ||
Humidity | Roll chart | 10 to 90% RH non-condensing | |
Fan fold | 15 to 80% RH non-condensing | ||
Vibrations | Frequency 10 to 60 Hz, amplitude 0.07 mm, 60 to150 Hz acceleration1g | ||
Accuracy | Reference conditions |
Temperature = 23ºC ± 2ºC (73ºF ± 3ºF) Humidity = 65% RH ± 5% Line voltage = Nominal ± 1% Source resistance = 0 Ohm Series mode and common |
|
Accuracy | Field calibration accuracy 0.05% of the selected range (IEC 873), Chart resolution : 0.18 mm (0.007"). Cold junction accuracy : ± 0.5ºC (32.9ºF) |