- Combustion
- Chart Paper & Pens
- Dampers & Actuators
- Controllers & Recorders
- Flow Meters & Level Sensors
- Humidity, Analytical & Gas
- HVAC Controls- Electric
- HVAC Controls- Pneumatic
- PLCs and Automation
- Pressure
- Temperature
- Valves
- VFDs & Electrical
- Wireless Devices
HONEYWELL
FIREYE
TEKMAR
IGNITION CONTROLS
GAS REGULATORS
WATER LEVEL CONTROLS
PUMPS AND PARTS
PRESSURE RELIEF VALVES
FIRING RATE MOTORS
PRESSURE SWITCHES & CONTROLS
COMBUSTION ANALYSIS INSTRUMENTS
CHART PAPER
DIRECT COUPLED
- Belimo Non-Spring Return Actuators
- Belimo Spring Return Actuators
- Honeywell Non-Spring Return Actuators
- Honeywell Spring Return Actuators
- Johnson Controls Non-Spring Return Actuators
- Johnson Controls Sping Return Actuators
- Schneider Electric Non-Spring Return Actuators
- Schneider Electric Spring Return Actuators
- Siemens Non-Spring Return Actuators
- Siemens Spring Return Actuators
FOOT MOUNTED
PNEUMATIC DAMPER ACTUATORS
FIRE & SMOKE ACTUATORS
HERCULINE ACTUATORS
RECORDERS
CONTROLLERS
DIGITAL PANEL METERS
ANALOG PANEL METERS
SIGNAL CONDITIONERS
TRANSDUCERS
VARIABLE AREA FLOW METERS
CORIOLIS MASS FLOW METERS
MAGNETIC FLOW METERS
PADDLE WHEEL FLOW METERS
TURBINE FLOW METERS
ULTRASONIC FLOW METERS
VORTEX FLOW METERS
FLOW SWITCHES
LEVEL METERS AND TRANSMITTERS
LEVEL SWITCHES
BW CONTROLS RELAYS
HUMIDITY
ANALYTICAL
- Honeywell 7866 Thermal Conductivity Analyzer
- Honeywell Thermal Conductivity Cells
- Honeywell HPW7000 Hi-pHurity Water System
- Honeywell pH ORP Electrodes
- Honeywell UDA2182 Analyzer
- Honeywell Toroidal (Electrodeless) Conductivity
- Honeywell Dissolved Oxygen
- Honeywell Directline Analyzer and Sensors
- GF Signet pH/ORP
- GF Signet Conductivity & Resistivity
- GF Signet Turbidity
- GF Signet Multi-Parameter Controller
INDUSTRIAL FIXED GAS DETECTION
BUILDING GAS DETECTION
PORTABLE GAS DETECTION
MISCELLANEOUS GAS DETECTION
THERMOSTATS
-
Digital Electronic Thermostats
-
Electronic Thermostats
TEMPERATURE CONTROLS
-
Remote Electronic Temperature Controls
-
Remote Bulb Temperature Controls
-
Limit Controls & Freezestats
-
Temperature Sensors
-
Humidity Sensors
BUILDING AUTOMATION SYSTEMS
HUMIDITY CONTROLS
ECONOMIZER CONTROLS
OTHER FIELD DEVICES & ACCESSORIES
CURRENT SENSORS
ALSO SEE
THERMOSTATS
HUMIDISTATS
VAV CONTROLLERS
PNEUMATIC SENSORS & CONTROLS
PNEUMATIC ACTUATORS
EP, IP, PE SWITCHES AND TRANSDUCERS
AIR STATION EQUIPMENT
PRESSURE GAUGES
Process Gauges
General Purpose Gauges
Low Pressure Gauges
Differential Pressure Gauges
Sanitary Gauges
Contractor Gauges
Commercial Gauges
Test Gauges
- Pressure Gauge Accessories
DIAPHRAGM SEALS
PRESSURE SWITCHES
PRESSURE TRANSMITTERS/TRANSDUCERS
THERMOMETERS
TEMPERATURE TRANSMITTERS
TEMPERATURE SWITCHES
THERMOWELLS
COMMERCIAL HVAC VALVES
- Belimo Globe Valves
- Belimo Ball Valves
- Belimo Butterfly Valves
- Belimo Zone Valves
- Erie Pop Top Zone Valves
- Honeywell Globe Valves
- Honeywell Zone Valves
- Invensys Barber Colman Globe Valves
- Johnson Controls Globe Valves
- Johnson Controls Ball Valves
- Johnson Controls Butterfly Valves
- Siemens Globe Valves
- Siemens Ball Valves
- Siemens Butterfly Valves
- Siemens Zone Valves
- Maxitrol Gas Regulator Valves
INDUSTRIAL VALVES
- Apollo Ball Valves
- Conbraco Pressure Relief Valves
- Condensate Drain Valves
- Dragon Valves
- Hancock Forged Steel Globe Valves
- JD Gould Valves
- NEWCO Forged Gate, Globe and Check Valves
- NEWCO Trinity Valve
- Newmans Gate, Globe and Check Valves
- Plastomatic Ball Valves
- Tasco Bronze Globe Valves
- Triac Ball Valves
- Warren Controls Valves
- Watts Safety Relief Valves and Accessories
- Yarway Blow-Off Valves
- Yarway Hy Drop Valves
- Yarway Steam Traps and Parts
- Yarway Welbond Valves
ACCESSORIES
ALSO SEE
VFDS
RELAYS AND CONTACTORS
CURRENT SENSORS
TRANSFORMERS
TIMERS
POWER SUPPLIES
ACCESSORIES
Home » Phoenix QUINT-PS-100-240AC/24DC/2.5 Single-Phase Primary-Switched Power Supply Unit
Phoenix QUINT-PS-100-240AC/24DC/2.5 Single-Phase Primary-Switched Power Supply Unit
Single-Phase Primary-Switched Power Supply Unit
QUINT-PS-100-240AC/24DC/2.5
Description:
QUINT POWER devices are 60...960 W DC power supply units for universal use. This is ensured by the wide-range input, single and three-phase versions, and an international approval package.
QUINT POWER stands for guaranteed supply: powerful capacitors ensure mains buffering of more than 20 ms at full load.
All three-phase devices provide the full output power, even in the event of a continuous phase failure. The POWER BOOST power reserve starts loads with high inrush currents and ensures that fuses are reliably tripped. Preventive function monitoring diagnoses impermissible operating states and minimizes downtimes in your system. An active transistor output and a floating relay contact are used for remote monitoring.
Specifications:
| Input data | ||
| Input nominal voltage range | 100...240 V AC | |
| AC input voltage range | 85...264 V AC, 90...350 V DC | |
| Frequency range | 45...65 Hz (0 Hz at DC input) | |
| Current consumption | 0.86 A (at 120 V AC (nominal load)), approximately 0.47 A (at 230 V AC (nominal load)), approximately |
|
| Inrush current surge | < 20 A (typical), inrush current limiting/Ι2t (25°C): < 2.2 A²s | |
| Mains buffering (for nominal load) | > 20 ms (at 120 V AC), > 100 ms (at 230 V AC) | |
| Typical switch-on time | < 1 s | |
| Protective circuit | Transient surge protection varistor | |
| Input fuse | 5 A (slow-blow, internal) | |
| Recommended backup fuse | Circuit breaker 6 A, 10 A or 16 A, Characteristic B | |
| Discharge current to PE | < 3.5 mA | |
| Connection method | COMBICON screw/plug-in connection | |
| Stripping length | 7 mm | |
| Output data | ||
| Nominal output voltage | 24 V DC ±1% | |
| Setting range of the output voltage | 22.5...28.5 V DC | |
| Output current | 2.5 A (-25...+60°C) 3.75 A (with POWER BOOST, -25...+40°C) |
|
| Derating | Above +60°C: 2.5% per Kelvin | |
| Maximum capacitive load | Unlimited | |
| System deviation | < 1% (static load change 10...90%) < 2% (dynamic load change 10...90%) < 0.1% (input voltage change ±10%) |
|
| Power dissipation | Maximum nominal load | 10 W |
| Maximum no load | 2 W | |
| Efficiency | > 86% for 230 V AC and nominal values | |
| Rise time | < 2 ms (UOUT (10...90%)) | |
| Residual ripple/switching peaks (20 MHz) | < 100 mVpp (for nominal values) | |
| Parallel connection | Yes, to create redundant systems and increase efficiency | |
| Internal surge protection | Yes, limited to 35 V DC, approximately | |
| Resistance to return supply | 35 V DC | |
| Connection method | COMBICON screw/plug-in connection | |
| Stripping length | 7 mm | |
| DC OK Signal Output, Active | ||
| Type of output | Transistor output, Uout > 0.9 x UN: High signal | |
| Continuous current | 40 mA, maximum | |
| Output voltage | +24 V DC (signal) | |
| DC OK Signal Output, Floating | ||
| Type of output | Relay contact, Uout > 0.9 x UN: Contact closed | |
| Continuous current | 1 A, maximum | |
| Maximum switching voltage | 30 V AC/DC, maximum | |
| General Data | ||
| Insulation voltage | Input/output | 4 kV AC (type test)/2 kV AC (routine test) |
| Input/PE | 3.5 kV AC (type test)/2 kV AC (routine test) | |
| Insulation voltage output/PE | 500 V DC (routine test) | |
| Mounting position | On horizontal NS 35 DIN rail according to EN 60715 | |
| Degree of protection | IP20 | |
| Protection class | Ι, with PE connection | |
| MTBF | > 500,000 h according to IEC 61709 (SN 29500) | |
| Housing version | AluNox (AlMg1), closed | |
| Weight | 0.850 kg | |
| Dimensions (width x height x depth) | 55 mm x 130 mm x 125 mm | |
| Dimensions (width x height x depth) for alternative assembly | 122 mm x 130 mm x 58 mm | |
| Status Indicators | ||
| DC OK status indicator | Green LED (Uout < 0.9 x UN: LED flashes) | |
| Climatic Data | ||
| Ambient temperature (operation) | -25...+70°C (> 60°C derating) | |
| Ambient temperature (storage/transport) | -40...+85°C | |
| Maximum permissible humidity (operation) | 95% (at +25°C, no condensation) | |
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm according to IEC 60068-2-6 15...150 Hz, 2.3g, 90 minutes |
|
| Shock | 30g in all space directions, according to IEC 60068-2-27 | |
| Pollution degree | 2 according to EN 50178 | |
| Climatic class | 3K3 according to EN 60721 | |
| Certification/Standards | ||
| Electrical equipment of machines | EN 60204 (Surge Voltage Category III) | |
| Safety transformers for switched-mode power supply units | EN 61558-2-17 | |
| Electrical safety (of IT equipment) | EN 60950/VDE 0805 (SELV), EN 61558-2-17 CB Scheme j UL/C-UL Recognized UL 60950 u |
|
| Industrial control equipment | UL/C-UL Listed UL 508 U | |
| Electrical equipment for potentially explosive areas | UL/C-UL Recognized UL 1604, Class Ι, Division 2, Groups A, B, C, D | |
| Shipbuilding | Germanischer Lloyd F, ABS | |
| Electronic equipment for use in electrical power installations | EN 50178 (VDE 0160) | |
| Safety extra-low voltage | PELV (EN 60204), SELV (EN 60950) | |
| Safe isolation | DIN VDE 0100-410, DIN VDE 0106-1010 | |
| Protection against electric shock | DIN 57100-410 | |
| Protection against electric shock, basic requirements for safe isolation in electrical equipment | DIN VDE 0106-101 | |
| Limitation of harmonic line currents | According to EN 61000-3-2 | |
| Device safety | (tested safety) | |
| Item | Description | Type | Pcs./Pkt. |
| 29 38 57 8 | Single-phase primary-switched power supply unit | QUINT-PS-100-240AC/24DC/2.5 | 1 |
| 29 38 19 6 | Assembly adapter for QUINT POWER 2.5 A and 5 A on S7 300 rails | QUINT-PS-ADAPTERS7/1 | 1 |
| Item | Description | Type | Pcs./Pkt. |
| 29 38 57 8 | Single-phase primary-switched power supply unit | QUINT-PS-100-240AC/24DC/2.5 | 1 |
| 29 38 19 6 | Assembly adapter for QUINT POWER 2.5 A and 5 A on S7 300 rails | QUINT-PS-ADAPTERS7/1 | 1 |










