Jump to Navigation

McCrometer V-Cone Universal Differential Flow Meter For Liquid Gas and Steam

Universal Differential Flow Meter For Liquid Gas and Steam
V-Cone

The McCrometer V-Cone Flowmeter technology accurately measures flow over a wide range of Reynolds numbers, under all kinds of conditions and for a variety of fluids. It operates on the same physical principle as other differential pressure-type flowmeters, using the theory of conservation of energy in fluid flow through a pipe.

• high accuracy
• high repeatability
• self conditioning
• minimum straight pipe requirements
• broad rangeability
• low headloss

Standard Accuracy: From ± 0.5% of actual flow (certain fluids and Reynolds number applications require special calibrations to achieve this value)
Repeatability: ±0.1% or better
Flow Ranges: 10:1 and greater
Standard Beta Ratios: 0.45 through 0.80, special betas available
Head Loss: Varies with beta ration and DP
Installation Piping Requirements: Typically 0-3 diameters upstream and 0-1 diameters downstream of the cone are required, depending on fittings or valves in the adjacent pipeline
Materials of Construction Include: Duplex 2205, 304, or 316 stainless steel, Hastelloy C-276, 254, SMO, carbon steels. Special materials on request
Line Sizes: 0.5” to 120” or larger
End Fittings: Flanged, threaded, hub or weld-end standard. Others on request
Configurations: Precision flow tube and wafer-type: Calibrated for customer application. ASME B31.3 construction available.
Approvals for the V-Cone: Canadian custody transfer approved
Meters in compliance with PED97/23/EC are available uponrequest
ISO 9001:2000 certified quality management system

• oil & gas production and delivery
• petroleum refining
• municipal water & wastewater
• chemical/pharmaceutical processing
• power/co-generation
• mining
• pulp & paper
• industrial manufacturing
• food & beverage



Main menu 2