Functional Devices RIB DRY CONTACT RELAYS Dry Contact Relays

Dry Contact Relays
DRY CONTACT RELAYS

The Dry Contact Input RIB series offers all the advantages of the standard RIB line; plus, it can be activated by a wide range of dry contacts such as thermostats, switches, other relays, solid-state switches, etc. The Dry Contact Input RIB provides the low-voltage (Class 2) power needed to activate the relay (self-powered) – just close the dry-contact input. The power to energize the relay can be brought to the relay on a separate pair of wires along with the control output of the controller, or can be a local power source near the relay. The relay contacts are isolated from the input power and the dry contact input; thus, they can be wired to switch any other power-load or low-voltage load (see specifications for contact ratings). One model can be used for many installations (model RIB21CDC can operate from any voltage from 120Vac – 277Vac; see specifications for the input power of other models).

Select a link under the "item" tab below to order.

Cat #TypeRelaysContactsResistiveMotorBallastTungstenPilot Duty.Override SwitchGold FlashPower Input
RIB01BDCENCLOSED DRY CONTACT INPUT RELAYS1SPDT20A2 HP20A1200W1110VA120
RIBD01BDCENCLOSED DRY CONTACT INPUT RELAYS1SPDT20A2 HP20A1200W1110VA120
RIBD01BDC-DOBENCLOSED DRY CONTACT INPUT RELAYS1SPDT20A2 HP20A1200W1110VA120
RIB02BDCENCLOSED DRY CONTACT INPUT RELAYS1SPDT20A2 HP20A1200W1110VA208-277
RIBD02BDCENCLOSED DRY CONTACT INPUT RELAYS1SPDT20A2 HP20A1200W1110VA208-277
RIB01SBDCENCLOSED DRY CONTACT INPUT RELAYS1SPDT20A2 HP20A1200W1110VA120
RIB02SBDCENCLOSED DRY CONTACT INPUT RELAYS1SPDT20A2 HP20A1200W1110VA208-277
RIB21CDCENCLOSED DRY CONTACT INPUT RELAYS1SPDT10A1/2 HP470VA120-277
RIB21CDC-N4ENCLOSED DRY CONTACT INPUT RELAYS1SPDT10A1/2 HP470VA120-277
RIB21CDC-RDENCLOSED DRY CONTACT INPUT RELAYS1SPDT10A1/2 HP470VA120-277
CLC212ENCLOSED DRY CONTACT INPUT RELAYS1SPDT10A1/2 HP470VA120-277
CLC106ENCLOSED DRY CONTACT INPUT RELAYS1SPDT5A5A5A120
RIBM01ZNDCPANEL MOUNT DRY CONTACT INPUT RELAYS1DPDT30A2 HP30A1640VA120
RIBM02ZNDCPANEL MOUNT DRY CONTACT INPUT RELAYS1DPDT30A2 HP30A1640VA208-277
RIBM013PNDCPANEL MOUNT DRY CONTACT INPUT RELAYS1TPDT20A7.5 HP20A1640VA120
RIBM023PNDCPANEL MOUNT DRY CONTACT INPUT RELAYS1TPDT20A7.5 HP20A1640VA208-277
RIBD01BDCTIME DELAY DRY CONTACT RELAYS1SPDT20A2 HP20A1200W1110VA120
RIBD01BDC-DOBTIME DELAY DRY CONTACT RELAYS1SPDT20A2 HP20A1200W1110VA120
RIBD02BDCTIME DELAY DRY CONTACT RELAYS1SPDT20A2 HP20A1200W1110VA208-27
RIBD02BDC-DOBTIME DELAY DRY CONTACT RELAYS1SPDT20A2 HP20A1200W1110VA208-27