Johnson Controls M9000 Electrically Actuated, Standard-Pressure, Standard-Temperature Two-Way Butterfly Valves

Two-Way Butterfly Valves
M9000 Electrically Actuated, Standard-Pressure, Standard-Temperature

VF Series M9000 Electrically Actuated, Standard-Pressure, Standard-Temperature Two-Way Butterfly Valves are specifically designed for a wide range of Heating, Ventilating, and Air Conditioning (HVAC) applications, including two-position and modulating control of hot, chilled, or condenser water, and 50/50 glycol solutions. These valves are also bidirectional, allowing positive shutoff with the flow in either direction. Two-way configurations are available in sizes from 2 through 6 in. non-spring return, and 2 through 5 in. spring return. M9000 electrically actuated, non-weather shield models feature an integral handle for manual positioning of the valve, independent of a power supply.

• low seating/unseating torques
• bubble-tight shutoff
• broad range of pre-assembled actuators
• compatible with all types of American National Standards Institute (ANSI) 125/150 slip-on and weld-neck flanges
• high-integrity components
• M9000 electric actuators available with or without a rugged, factory-installed weather shield
• M9000 electric actuators available with or without end switches

Select a link under the "item" tab below to order.

Cat #TypeType1Type2Size, in.Cv at 90°Cv at 70°Closeoff Pressure (psig)¹Type3
VFN020HB+92NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Open214484175Two-Way – Spring Return
VFN025HB+92NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Open2-1/2282163175Two-Way – Spring Return
VFN030HB+92NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Open3461267175Two-Way – Spring Return
VFN040LB+92NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Open484149650Two-Way – Spring Return
VFN040HB292NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Open4841496175Two-Way – Spring Return
VFN050LB292NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Open5137677550Two-Way – Spring Return
VFC020HB+94NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Closed214484175Two-Way – Spring Return
VFC025HB+94NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Closed2-1/2282163175Two-Way – Spring Return
VFC030HB+94NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Closed3461267175Two-Way – Spring Return
VFC040LB+94NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Closed484149650Two-Way – Spring Return
VFC040HB294NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Closed4841496175Two-Way – Spring Return
VFC050LB294NAGAM9220-AGA-3 without End SwitchesFloating ControlSpring Closed5137677550Two-Way – Spring Return
VFN020HB+92NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Open214484175Two-Way – Spring Return
VFN025HB+92NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Open2-1/2282163175Two-Way – Spring Return
VFN030HB+92NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Open3461267175Two-Way – Spring Return
VFN040LB+92NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Open484149650Two-Way – Spring Return
VFN040HB292NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Open4841496175Two-Way – Spring Return
VFN050LB292NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Open5137677550Two-Way – Spring Return
VFC020HB+94NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Closed214484175Two-Way – Spring Return
VFC025HB+94NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Closed2-1/2282163175Two-Way – Spring Return
VFC030HB+94NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Closed3461267175Two-Way – Spring Return
VFC040LB+94NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Closed484149650Two-Way – Spring Return
VFC040HB294NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Closed4841496175Two-Way – Spring Return
VFC050LB294NAGCM9220-AGC-3 with Two End SwitchesFloating ControlSpring Closed5137677550Two-Way – Spring Return
M9000 Electrically Actuated, Standard-Pressure, Standard-Temperature, Two-Way Butterfly Valves (without Weather Shield)
Service: Hot, Chilled, or Condenser Water, and 50/50 Glycol Solutions (Not designed for use in steam applications.)
Body Styles and Sizes: Two-Way, 2 through 6 in., Fully Lugged
Fluid Temperature Limits: -40°F to 250°F (-40°C to 121°C)
Body Pressure Rating: 175 psig
Maximum Fluid Velocity: 30 ft/second (9 m/second)
Rangeability: Refer to the VF Series Standard-Pressure, Standard-Temperature Butterfly Valves Product Bulletin (LIT-977205P)
Leakage: Bubble Tight
Flow Characteristics: Modified Equal Percentage
Materials:     Body Cast Iron, ASTM A126 Class B
Tee
(Three-Way Valves Only)
Cast Iron
Disc Ductile Iron, Nylon 11 Coated, ASTM A536 Gr 65-45-12
Seat Ethylene Propylene Diene Monomer (EPDM)
Stem 416 Stainless Steel
Ambient Temperature Limits:  Storage -20 to 150°F (-29 to 66°C), Preferably 40 to 85°F (4 to 29°C)
Operating Spring Return Actuator: -40 to 131°F (-40 to 55°C)
Non-Spring Return Actuator: -4 to 122°F (-20 to 50°C)
Weather Shield Rating: National Electrical Manufacturers’ Association (NEMA) 4