Honeywell Y8610U Universal Retrofit Intermittent Pilot Gas Burner Ignition Systems

Universal Retrofit Intermittent Pilot Gas Burner Ignition Systems
Y8610U

Complete kits converting conventional standing pilot system to intermittent pilot system. For use with 24 Vac gas-fired atmospheric furnaces, boiler and heating appliances.

• Y8610U kits are for use with natural or LP gas: provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated.
• Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed.

Select a link under the "item" tab below to order.

Cat #Pre PurgeFlame Failure Responce Time (sec)IncludesIgnition Trial Time (sec)Ignition Trials To LockoutLockout Timing
Y8610U40010 or 30 seconds2.0 secVR8204A2142 valve (1/2 x 1/2; 3.5 in. WC setting; 150 kBtu/hr at 1 in. p.d.)15 or 90 secondscontinuous retry15 or 90 seconds
Y8610U60060 or 30 seconds2.0 secVR8304M3558 (1/2 x 3/4; 3.5 in. setting; 270kBtu/hr at 1 in. p.d.)15 or 90 secondscontinuous retry15 or 90 seconds
Application Provide electronic control of intermittent pilot ignition systems used on gas fired furnaces, boilers, and other heating appliances
Dimensions, Approximate 3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep (100 mm high x 138 mm wide x 67 mm deep)
Type of Gas

Natural or LP

Electrical Ratings 24 Vac
Frequency 60 Hz
Flame Sense Single Rod or Two Rods
Ignition Sequence Continuous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place
Ignition Source Internal high voltage spark generator
Ignition System Type Intermittent Pilot
Maximum Valve Load @ 24 Vac (Amps)

1A Pilot, 2A Main @ 24Vac

Typical Gas Control VR8204, VR8304
Typical Ignition Hardware Q345, Q3451
Maximum Ambient Temperature (-40 C to +74 C) -40 F to +165 F