Honeywell WA/WG500 Series Wireless Pressure Transmitters

Wireless Pressure Transmitters
WA/WG500 Series

XYR 5000 wireless pressure transmitters give you the ability to transmit data from areas where hard-wired measuring devices have been too costly, difficult or time consuming.

The power and simplicity of the XYR 5000 transmitters will allow you to easily and economically increase the number, type and frequency of measurements you make in monitoring your process.

 

 

Select a link under the "item" tab below to order.

Cat #DescriptionsType
WG511Gauge Pressure Transmitter, 0-30psig (2 bar)Gauge Pressure Transmitters
WG512Gauge Pressure Transmitter, 0-250psig (17.2 bar)Gauge Pressure Transmitters
WG513Gauge Pressure Transmitter, 0-1000psig (69 bar)Gauge Pressure Transmitters
WG514Gauge Pressure Transmitter, 0-5000psig (345 bar)Gauge Pressure Transmitters
WG519Gauge Pressure Transmitter, 0-10000psig (689 bar)Gauge Pressure Transmitters
WA515Absolute Pressure Transmitter, 0-30psig (2 bar)Absolute Pressure Transmitters
WA516Absolute Pressure Transmitter, 0-250psig (17.2 bar)Absolute Pressure Transmitters
All transmitters:
RF: RF: License Free. Frequency Hopping Spread
Spectrum Technology
Sensors power: "C" size 3.6 V Li
Range : 2000 It. (61Om)
Battery Life: Up to 5 years
Diagnostics: Low battery, "Out of spec"
Event Driven transmission rates
Local and Software Configurable
Local display
Hazardous Approvals: FM & CSA Class I, Division II, Groups A, B, C, D
ATEX EEx ia IIC EEx NI IIC with CE Mark
NEMA Type 4X, IP 66
Differential Pressure:
Ranges: 100" H20 (24.91 kPa). 300" H20 (74.73 kPa) ,
25 psi (172.37 kPa), 100 psi (698,48 kPa) and
300 psi (20.68 bars)
Accuracy: 0.2%
NEMA: Type 4X
Approvals: General Industry Non-hazardous
Gauge Pressure:
Ranges: 30, 250, 1000 and 5000 psi
(206 .84 kPa, 17.24 bars. 68.95 bars, 344.74 bars)
Accuracy: 0.1%
Absolute Pressure
Ranges: 30 and 250 psi (206 .84 kPa and 17.2 bars)
Temperature + DI: TC and RTD
Includes Discrete Input Option
Accuracy: 0.1%
Remote Probe Configuration is NEMA 4
Analog Input: 4-20 ma I 0-1OV
Includes Discrete Input Option
Accuracy: 0.1%
Two Inputs
Discrete Inputs: Dry contact only, no voltage or current
1 Kohm maximum impedance
Two inputs
Acoustic: Up to 25 Modules per base radio
Three options: 4 AO, 8 DO. 4 AO /800
Base Radio: Multiple devices per base radio
Power: 24 VDC
NEMA: Type 4
Local display
Operating Temperature: -40 °C to 85 °C [-40 of to 185 OF]
External Antennas: Integrated Yagi (analog and temperature units) for ranges up to 5000 ft. (1500m)
Remote High Gain for ranges up to 5000 ft. (1500m)


Main menu 2