Jump to Navigation

Honeywell S8610U Universal Intermittent Pilot Module

Universal Intermittent Pilot Module
S8610U

Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) Intermittent Pilot Ignition Modules. Provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers, and other heating appliances.

• Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances.
• Provides 100 percent pilot gas shutoff if pilot fails to light; after 6- minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed.
• For use with Natural or LP gas.
• For use in single rod or dual rod/remote sense applications. Includes relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended.
• Functional equivalent of S86, S8600, S8610 and S90 modules.
• Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable.

Select a link under the "item" tab below to order.

Cat #Pre PurgeFlame Failure Responce Time (sec)IncludesIgnition Trial Time (sec)Between Trial Time (sec)Ignition Trials To LockoutLockout Timing
S8610U3009Configurable to 30 seconds or no prepurge2 seconds maximumDamper connection with automatic vent damper plugcontinuous retry5 minute delay after failed trial for ignition.continuous retryConfigurable to 15 seconds or 90 seconds
Application One or Two Rod Intermittent Pilot Control with continuous retry trial time with configurable lockout timing of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurge
Dimensions, Approximate 3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep (100 mm high x 138 mm wide x 67 mm deep)
Type of Gas Natural or LP
Electrical Ratings 24 Vac
Frequency 50/60 Hz
Flame Sense Single Rod or Two Rods
Ignition Sequence Continuous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place
Ignition Source Internal high voltage spark generator
Ignition System Type Intermittent Pilot
Maximum Valve Load @ 24 Vac (Amps) 1A Pilot, 2A Main @ 165 F;
1A Pilot, 1A Main @ 175 F
Typical Gas Control VR8204, VR8304
Typical Ignition Hardware Q345, Q3451, Q3452
Maximum Ambient Temperature (-40 C to +74 C) -40 F to +165 F
Approvals Canadian Standards Association: Design Certified