Jump to Navigation

Honeywell LP916 Pneumatic Thermostat

Pneumatic Thermostat
LP916

Two-pipe, single temperature, unit mounted, remote bulb pneumatic thermostat used to provide proportional control of pneumatic valves and damper actuators in heating and air conditioning systems.

• Liquid filled remote bulb.
• Direct Acting (DA), Reverse Acting (RA) and Heating/Cooling (DA/ RA) models are available.

Select a link under the "item" tab below to order.

Cat #CommentsIncludesActionChangeoverSensor ElementSetting Temperature RangeThrottling RangeScale Markings
LP916A1019-Integral Mounting Bracket and 304528A Bag Assembly (mounting hardware). Order bulb hangers (316297-00021) sparately.Direct Acting-Bulb 1/2 x 5 7/8 in., capillary 36 in. (914mm) long65 F to 85 F3.5 FWarmer / Cooler
LP916A1134-Integral Mounting Bracket, (2) 316297-00021 Bulb Hangers and 304528A Bag Assembly (mounting hardware).Direct Acting-Bulb 3/8 x 7 in., capillary 36 in. (914 mm) long65 F to 85 F3.5 FWarmer / Cooler
LP916A1175-Integral Mounting Bracket, (2) 316297-00021 Bulb Hangers and 304528A Bag Assembly (mounting hardware).Direct Acting-Bulb 3/8 x 7 in., capillary 36 in. (914 mm) long40 F to 80 F7 F40 F to 80 F
LP916B1017-Integral Mounting Bracket and 304528A Bag Assembly (mounting hardware). Order bulb hangers (316297-00021) separately.Direct Acting Heating, Reverse Acting CoolingHeat 18 psi, Cool 13 psiBulb 1/2 x 5 7/8 in., capillary 36 in. (914 mm) long65 F to 85 F3.5 FWarmer / Cooler
LP916B1058-Integral Mounting Bracket and 304528A Bag Assembly (mounting hardware). Order bulb hangers (316297-00021) separately.Direct Acting Heating, Reverse Acting CoolingHeat 18 psi, Cool 9 psiBulb 1/2 x 5 7/8 in., capillary 36 in. (914 mm) long65 F to 85 F3.5 FWarmer / Cooler
LP916B1074-Order Mounting Bracket, Knob, Bulb Hangers, and Scale Plate separately.Direct Acting Heating, Reverse Acting CoolingHeat 18 psi, Cool 13 psiBulb 3/8 x 7 in., capillary 36 in. (914 mm) long65 F to 85 F3.5 FWarmer / Cooler
LP916B1082New installation modelIntegral Mounting Bracket, (2) 316297-00021 Bulb Hangers and 304528A Bag Assembly (mounting hardware).Direct Acting Heating, Reverse Acting CoolingHeat 18 psi, Cool 13 psiBulb 3/8 x 7 in., capillary 36 in. (914 mm) long65 F to 85 F3.5 FWarmer / Cooler
LP916B1090-Integral Mounting Bracket, (2) 316297-00021 Bulb Hangers and 304528A Bag Assembly (mounting hardware).Direct Acting Heating, Reverse Acting CoolingHeat 18 psi, Cool 13 psiBulb 3/8 x 9 in., capillary 36 in. (914 mm) long65 F to 85 F3.5 FWarmer / Cooler
LP916C1023-Integral Mounting Bracket, (2) 316297-00021 Bulb Hangers and 304528A Bag Assembly (mounting hardware).Reverse Acting-Bulb 3/8 x 9 in., capillary 36 in. (914 mm) long60 F to 80 F3.5 F60 F to 80 F
Application Type: Unit Ventilator
Dimensions, Approximate: 4 3/4 in. high x 3 3/4 in. wide x 3 in. deep
(121 mm high x 95 mm wide x 76 mm deep)
Airflow Usage: 0.022 scfm (10.4 mL/s) with 0.007 in. restriction
Air Connections: Barb fittings 1/4 in. (6 mm)
Mounting: In compartment of a unit ventilator
Operating Temperature: 135 F maximum (57 C maximum)
Storage Temperature: 150 F maximum (66 C maximum)
Remote Bulb: Yes
Sensor Element: Bulb 1/2 x 5 7/8 in., capillary 36 in. (914 mm) long
Number of Pipes: 2
Setpoint: Single
Maximum Operating Pressure: 25 psi (170 kPa)

 

 

 

 

 

 

 

 

 

 