Jump to Navigation

Honeywell Impact personal multi-gas detectors Lumidor Impact & Impact Pro

Lumidor Impact & Impact Pro
Impact personal multi-gas detectors

Impact portable gas detectors bundle feature-rich advantages into a unit offering a low cost of ownership. Available in two configurations (Impact & Impact Pro), Impact models accept serviceable and/or disposable cartridges, are pre-calibrated and ready to go from the box.

The Impact gas detectors are safe, small, lightweight, battery-powered and rugged — ideal for areas where exposure to toxic or flammable gases poses a risk. You benefit from one touch calibration, cartridge replacement in less that one minute, and IP67 rated durable housing that protects against dust/water ingress. Our unique cartridge design (with up to 4 sensors in a self-contained plug-in cartridge) allows you to change all sensors at once—for about the cost of a typical single sensor. Options include advanced infrared sensors, Safelink confined-space instrument to- instrument communication, unpowered low-flowrate Enforcer gas calibration/bump test station, rechargeable battery and more.

Reliable Operation
• Pre-calibrated plug-in sensor cartridge
• Patented Surecell™ toxic sensors
• Stable and accurate

Easy to Use
• One button on/off
• Multi-lingual, intuitive menu system
• On screen prompts guide user
• Built-in correction factors for flammable gases
• Enhanced data logging capability as standard with up to 200 hours of continuous data storage for all channels of gas detected

Easy to Maintain
• Plug-in operation for all serviceable parts
• Cartridge replacement in less than one minute
• Re-calibration in less than two minutes when using Enforcer
• Minimized cost of ownership Durable Housing
• Waterproof to IP67
• Rugged and impact resistant
• Built for everyday use

Advanced Optional Features
• Unpowered low-flow-rate allows up to 200 calibrations per gas cylinder
• Easy to calibrate with the unique Enforcer (% LEL sensor only) un-powered calibration station that completely automates bump testing and gas calibration
• Intrinsically safe communications technology between operator and attendant using the advanced SafeLink™ cable option between two Impact Pro units
• Excellent battery life using rechargeable NiMH batteries
• Precise infrared sensing technology Alarm Indication
• 3 levels of instantaneous alarm, time weighted average alarms on toxic
• Periodic confidence flash and bleep
• Increasingly rapid flashing, ultra-bright alarm LEDs
• Powerful two tone audible alarm
• Vibrating alarm for noisy environments
• Safelink communications User Friendly Pre-entry Check
• Peak hold function and drop line
• Hand aspiration
• Built-in automatic pump Impact Pro model only

Impact Sensor Cartridge Specifications
Use For use with Impact and Impact Pro portable multi-gas monitor for the protection of personnel from up to four hazardous
gases in the working environment.
Techniques used Flammable - Catalytic bead/pellistor
Toxic/oxygen - Electrochemical
Toxic/Flammable - Infared Cell
Sensor Technology
Detectable Gases Code Range Disposable Serviceable
Catalytic Bead IR Cell Electrochemical
Oxygen (O2) O 0-25 % v/v Always fitted Always fitted     x
Flammable F 0-100 % LEL Always fitted One Catalytic Sensor
Always Fitted
x    
Flammable IR %LEL R 0-100 % LEL Not available IR Sensor Always Fitted   x  
Flammable IR %VOL V 0-100 % VOL Not available IR Sensor Always Fitted   x  
Carbon Monoxide (CO) C 0-500 ppm 0 0     x
Hydrogen Sulfide (H2S) H 0-50 ppm O 0     x
Sulfur Dioxide (SO2) S 0-20 ppm O       x
Chlorine (Cl2) L 0-10 ppm   O     x
Nitrogen Dioxide (NO2) N 0-20 ppm   O     x
Ammonia (NH3) A 0-100 ppm   O     x
Carbon Dioxide (CO2) D 0-2% v/v   O     x
Carbon Dioxide (CO2) IR T 0 – 5 %V/V   O   x  
Notes:  Serviceable cartridges only available in 1 or 4 channel configurations.  All OFCH, OFC, OFH and OF are disposable only. C or H sensors only available for use in 4 gas Serviceable cartridges. † Infrared sensor cartridge models include one IR catalytic sensor for detecting flammable %LEL, %VOL or carbon dioxide; three additional electrochemical sensors are provided for detection of two toxic gases and oxygen.
Construction Easy fit single captive screw with asymmetric design to prevent incorrect fitting by user.
RFI shielded polypropylene caseworks for increased reliability and performance.
Operating temperature -4°F to +131°F (-20°C to 55°C) for all gas sensors except Carbon Dioxide (Electrochemical) and Ammonia
Carbon Dioxide (Electrochemical):32°F to 104°F ( 0°C to 40°C) Carbon Dioxide: (Electrochemical) 6 months maximum
Ammonia: -4°F to 104°F (-20°C to 40°C)
Storage temperature Cartridge and replacement sensors: -10ºC to 60ºC /14ºF to 140ºF (6 months maximum) for all gases except Carbon Dioxide
(Electrochemical) and Ammonia Carbon Dioxide (Electrochemical): 14°F to 104°F /-10C to 40C (6 months maximum)
Ammonia: 14°F to 104°F /-10°C to 40°C (6 months maximum)
Humidity range Continuous 20 to 90%RH.
Intermittent 0-99%RH non-condensing.
Approvals
Only applicable when used with Impact (Pro) instrument
Class 1, Div 1, Groups A, B, C, D (UL, CSA).
Standard supply Each cartridge is supplied in sealed container complete with installation instructions, calibration certificate and spare pump seal
Optional Accessories Cartridges can be re-programmed and re-calibrated via the Impact and Impact Pro instrument and optional base station and PC based Impact
Configuration Utility. (Not all cartridge configurations are available. Contact your Honeywell Analytics representative for more information/ availability)
Impact Specifications
Use Portable multi-gas monitor for the protection of personnel from up to four hazardous gases in the working environment.
User interface Ultra clear, backlit, alphanumeric display. Intuitive push button menu system with user selectable operation in English, French, German, Italian, Spanish and Dutch. Other languages available upon request.
Configuration and data download Supplied configured, ready to use including black box data-logging as standard. Configurable via optional PC software and base station for enhanced control of logging functions and data download.
Construction Impact resistant plastic, anti-static to EN50014.
Dimensions 1.9" x 3.3" x 5.3" (49mm x 84mm x 136mm) .
Weight Maximum 520g (18oz) including rechargeable battery and optional pump.
IP rating IP67 (Minimum).
Operating temperature -4°F to +131°F (-20°C to +55°C)
Storage temperature Instrument -40°F to +176°F. (-40°C to +80°C)
Humidity range Continuous 20 to 90%RH. Intermittent 0-99%RH non-condensing.
Alarms 3 levels of instantaneous alarm per channel. Time weighted average alarms on toxic channels.
Supplied pre-set (user configurable via optional PC software and base station).
Audible alarm Periodic confidence bleep with differing dual tone for fault, gas alarm and warning rated 85dBA at 1m (90dBA at 1ft).
Visual alarm Green confidence flash with rapid red flashing for fault, gas alarm and warning indication.
Battery performance Ni-MH rechargeable, operating life > 10 hours (Charging time 7 hours). Dry cell disposable > 17 hours. Nominal reduction of 10% when used with pump.
Optional pump Supplied as standard with Impact Pro. Typical flow rate 0.3l/min.
Automatic start/stop feature with auto-test on start-up and flow fail alarm.
Approvals USA: Class 1, Div 1, Groups A, B, C, D (UL).
Canada: Class 1, Div 1, Groups A, B, C, D (CSA).
Marine: Marine Equipment Directive MED 96/98/EC.
Standard supply Each instrument is supplied complete with quick start guide, multi-lingual operating instructions on CD, dry cell battery holders
and batteries, belt clip and flow adaptor. Fully configured and ready to accept either disposable or serviceable sensor cartridges
the key considerations in selecting either the Impact or Impact Pro are highlighted below.
Variations   Impact Impact Pro/Impact Pro IR
Cartridge type Disposable only Disposable or Serviceable
Integral pump/pump adaptor No Yes
Vibrating alarm No Yes
Safelink No Yes


Main menu 2

about seo