Jump to Navigation

GF Signet 5600 Series Batch Controller

Batch Controller
5600 Series

The Signet 5600 Batch Controller provides control capability and process fine-tuning in a familiar package. The programming interface uses a four-button keypad and an intuitive procedure for adjusting a batching system to the best performance possible.

The standard ¼ DIN package houses an analog display panel that features a batch status indicator with count-up or countdown dials. The backlit LCD displays flow rate and volume information and batch status, as well as calibration and setup instructions. The front of the unit is NEMA 4X/IP65 and is hard-coated, high-impact and UV resistant polycarbonate.

The 5600 operates on 12 to 24 volts ±10%, regulated, either AC or DC . Removable terminal connections make wiring the 5600 easy. Connect any Signet flow sensor with a frequency output, then add connections to two relays for two-stage shutdown or overrun alarm functions, connect a remote start-stop switch and use the end-of-batch pulse to trigger the next step in the process. A 4 to 20 mA output is also available. Advanced features include a user-set security code, an automatic calibration option, and overrun compensation.

• Permanent and resettable totalizers
• Non-volatile memory
• Easy batch volume entry
• Remote start, stop & resume
• Two-stage shutdown control
• Manual or automatic overrun compensation
• Estimates time to batch completion
• Overrun alarm and missing signal alarm
• Advanced valve control
• End-of-batch trigger
• Count-up or count-down to batch completion

Select a link under the "item" tab below to order.

Cat #DescriptionsCode
3-5600Batch Controller198 825 006
General
Operating Range 0.5 Hz to 10 kHz, optically isolated
Accuracy ± 0.5% of reading
Display
Analog Reversible dial - 0 to 100% or 100 to 0%
Digital Backlit LCD, 2 x 16 alphanumeric character.
Batch Size 0 to 999,999 engineering units
Dual Totalizer 8-digit resettable and non-resettable
Additional Functions End of batch pulse, remote start, stop & resume. Batch in progress. Batch completion, valve control or end of batch
Option Two-stage shutdown, overrun alarm, end of batch, or missing signal alarm
Materials
Enclosure ABS Plastic
Keypad Silicone Rubber
Panel and case gasket Neoprene
Window Hard-coated polycarbonate
Electrical
Power Requirements 12 to 24 VAC or DC ±10%, regulated recommended, 50 to 60 Hz, 10W max.
Current Output • 4 to 20 mA, non-isolated, active, internally powered
• Loop Impedance:350 Ω max. @ 12 V, 950 Ω max. @ 24 V
Accuracy ± 0.1%
Alarm Contacts Two SPDT relays: 5 A @ 30 VDC, 5 A @ 125 VAC, 3 A @ 250 VAC max.
Environmental
Operating Temperature. -10 °C to 55 °C (14 °F to 131 °F)
Relative Humidity 0 to 95%, non-condensing
Enclosure NEMA 4X/IP65
Shipping Weight 0.8 kg 1.8 lb
Standards and Approvals • CE, UL, CUL
• Manufactured under ISO 9001 for Quality and ISO 14001 for Environmental Management