Browse by Manufacturer

# Product Code Quantity
1
2
3
4
5

GE AF-600FP Fan and Pump Drive

GE
Fan and Pump Drive
AF-600FP

The AF-600FP™ Fan and Pump Drive is a powerful, flexible, and easy to use AC variable torque drive ideally suited for HVAC, compressor, and pump applications. The drive is available in a standard configuration that includes IP20 or IP00 Chassis, LCD Keypad Display that can be remote mounted, DC Link Reactors, built-in Modbus RTU, Metasys N2, Apogee FLN P1, and RFI Class A2 Filter. Models are available at 208/230V from 1 to 60HP, 460V from 1 to 1350HP, and 575V from 1 to 1350HP. Standard features like motor auto tuning, four auto-tuning PID controls, energy savings mode, and energy monitoring make the AF-600FP™ ideal for all your fan, pump, compressor, and blower applications. Its Quick Menu, Application Macros, and intuitive Keypad make it a time saver for start-up and commissioning. Optional LonWorks and BACnet communications modules along with IP55/54 NEMA 12 rated units allows it to be integrated into your building automation systems and stand-alone installations. Optional I/O modules and conformal coatings allow it to be used in complex or very harsh environments if needed. The AF-600FP™ is Plenum rated for mounting inside air handling ducts.

• IP20 or IP00 Chassis
• LCD Keypad
• DC Link Reactors
• Modbus bulletin
• Auto tuning
• Process PID Controller
• Metasys N2
• Apogee FLN P1
• Energy Savings mode
• LonWorks optional

Select a link under the "item" tab below to order.

Table 1Table 2Table 3Table 4Table 5Table 6Table 7Table 8Table 9Table 10Table 11
XXXXXXXXXXXXXXXX
Table 1Description
6KGE Product Code
Table 2Drive
FPAF-600 Fan and Pump Drive
Table 3Input Voltage
2208/230V, 50/60 Hz
4460V, 50/60 Hz
5575V, 50/60 Hz
Table 4Input Phase
11-Phase
33-Phase
Table 5HP Rating
F501/2 HP
01010 HP
100100 HP
1K01000 HP
Table 6Factory Installed Keypad
XKeypad
Table 7Drive Type
1IP21/Type 1
2IP55/NEMA 12
9IP20/Open
8IP00/Open
Table 8A1/B1 RFI Filter
XNo A1/B1 RFI Filter Installed
RA1/B1 RFI Filter Installed
Table 9Future Use
XStandard Unit
Table 10Conformal Coating
XNo Conformal Coatings
CConformal Coatings
Table 11Revision
A11st Revision
A2Future
Environmental Conditions
Enclosure IP20 Chassis, IP00 Chassis,
IP21/NEMA 1, IP55/NEMA 12,
IP54/NEMA 12
Plenum Ratings Drives and options are UL rated for installation inside air handling ducts and plenums
Installation Location Do not install in locations where product could be exposed to dust, corrosive gas, inflammable gas, oil mist, vapor, water drops or direct sunlight. There must be no salt in the atmosphere. Condensation must not be caused by sudden changes in temperature. For use at altitudes of 3280 ft. (1000M) or less without derating.
Storage Temperature -25° to 65°C
Ambient Temperature -10° to +50°C (24 hour average max of 45°C)
Ambient Humidity 5 to 95% RH (non-condensing)
Vibration 1.0g
Cooling Method Fan Cooled all ratings. Fan Control Auto, 50% level, 75% level, 100% level adjustable
Standards
Approvals CE, UL, cUL, and C-Tick Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes for 208/230V and 460V.
Input Power Supply
Rated Input AC Voltage 200-240 Vac, 3-phase, 50-60 Hz, +/- 10% V
380-480 Vac, 3-phase, 50-60 Hz, +/- 10% V
525-600 Vac, 3-phase, 50-60 Hz, +/- 10% V
Maximum Voltage Imbalance 3% of rated supply voltage
True Power Factor > 0.9 nominal at rated load
Displacement Power Factor > 0.98
Switching on input power supply Maximum twice/minute up to 10HP, Maximum once/minute above 10HP
Environment according to EN60664-1 Overvoltage category III/pollution degree 2
DC Link Reactors Built-In DC Link Reactors on all ratings
RFI Filters Built-In RFI Filters to reduce noise generated by the drive. Meets industrial standards.
Output
Rated Output Voltage 0-100% of supply voltage
Output Frequency 0-1000 Hz; 0-800Hz for 460V above 125HP and 525-690 V
above 125HP
Switching on output Unlimited
Accel/Decel Times 1-3600 seconds
Control Method Sinusoidal PWM Control (V/Hz, Avd. Vector Control)
Control
Starting Torque 110% starting torque for 1 minute (variable torque)
Carrier Frequency (Motor Noise) Selectable - 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 7, 8, 10, 12, 14, 16 kHz
Torque Boost 0 - 300% setting to compensate voltage in relation to the load at low speed
Acceleration/Deceleration Time 0.01-3600 seconds (4 acceleration and deceleration times are selectable via digital inputs. Acceleration and deceleration patterns can be selected from linear or S-curve)
Data Protection Password Protection for Quick Menu or Main Menu, 0-9999.
Pattern Operation Settings via Built-In Logic Controller Sequencer
Jump Frequency Control 4 jump (or skip) frequencies via parameter set to avoid mechanical vibration
Slip Compensation Maintains motor at constant speed with load fluctuations
Torque Limit Control Output torque can be controlled within a range of 0.0 to 110% (0.1 and steps)
8 Preset Speeds 8 programmable preset speeds selectable by 3 digital inputs
Preset Speeds 8 presets via digital inputs
Built-In Communications Drive RS-485, Modbus RTU, Metasys N2, or Apogee FLN P1
Trim Reference Setting Available for speed reference offset via potentiometer, voltage input, or current input
DC Injection Braking Starting frequency: 0.0-1000 Hz, 0-800Hz for 460V above 125HP and 525-690 V above 125HP Braking time: 0.0-60.0 seconds
Braking level: 0-100% of rated current
Jogging Operation Operation via On key or digital input (Fwd or Rev)
Auto-Restart After Power Failure Restarts the drive without stopping after instantaneous power failure
Energy Savings Controls output voltage to minimize motor loss during constant speed operation
Start Mode Function This functionality smoothly catches a spinning motor
Fire Override Mode Overrides drive's protective features and keeps motor
running
Pump Cascade Controller Distributes running hours evenly over up to 4 pumps
Sleep Mode Drive detects low or no flow conditions and adjusts
output
Dry Pump Detection Detects pump operation and can set off alarm, shuts off, or other programmed actions
Belt Monitoring Drive can detect relationship between current and speed to recognize a broken belt
Real Time Clock With programmable timed actions
Logic Controller (LC)
Logic Controller Events Up to 38 Programmable Events
Comparators Array of 6 Comparators
Timers Array of 8 Timers, adjustable from 0.0 to 3600 sec
Logic Rules Array of 6 Boolean Logic Rules
Logic Controller States Array of 20 Logic Controller Action States