Fireye MicroM Amplifier Modules

Amplifier Modules
MicroM

The Fireye MEUV1, MEUV4, MEUVS1, MEUVS4, MERT1, MERT4, MEIR1, MEIR4, MECD1 and MECD4 are Amplifier Modules used with the Fireye Modular MicroM control. These amplifier modules provide flame scanning capabilities using any of the Fireye standard ultraviolet scanners, self-check scanners, infrared scanners, cadmium sulfide scanners and flame rods. The Flame Failure Response Time (FFRT) of the control is determined by the selection of the amplifier module (see Ordering Information). Test jacks are provided on the amplifier modules to permit flame signal measurement during operation and is a uniform 0-10 vdc for all models. After scanner selection, the proper amplifier module must be used in the Modular MicroM chassis (see Ordering Information). The amplifier module incorporates a plug-in design for ease of installation. The programmer module determines the operational characteristics of the control (e.g. relight, purgetiming, etc.). For proper and safe application of this product, you must refer to bulletin MC-5000 for a detailed description of the operation of the Modular MicroM control, including installation instructions, operating sequences for the programmer modules, etc. Also follow the scanner installation and wiring instructions found in bulletins MC-5000 for proper flame scanning operation.

• Flame scanning capabilities
• Self-check scanners, infrared scanners, cadmium sulfide scanners and flame rods
•Test jacks are provided on the amplifier modules to permit flame signal measurement during operation and is a uniform 0-10 vdc for all models

Select a link under the "item" tab below to order.

Cat #Flame Amplifiers
MEDC2Amplifier for use with dry contact input from 85UVF-WR flame scanner, 0.30 sec FFRT. Use with MEP237 and 85UVF4- 1QDWR, 85IRF4-1QDWR, or InSight scanner (with 59-497- 020WR cable).
MEUV1UV amp, 0.8 sec FFRT. Use with UV1, UV2, 45UV3.
MEUV4UV amp, 3 sec FFRT. Use with UV1, UV2, 45UV3.
MEUVS1UV self check amp, 0.8 sec FFRT. Use with 45UV5-1008, -1009.
MEUVS4UV self check amp, 3 sec FFRT. Use with 45UV5-1008, -1009.
MERT1Flame rect amp. 0.8 sec FFRT. Use with 69ND, 45CM.
MERT4Flame rect amp. 3 sec FFRT. Use with 69ND, 45CM.
MEIR1Infrared amp, 0.8 sec FFRT. Use with 48PT2 scanner.
MEIR4Infrared amp, 3 sec FFRT. Use with 48PT2 scanner.
MECD1Cadmium sulfide amp, 0.8 sec FFRT. Use with C554A scanner.
MECD4Cadmium sulfide amp, 3 sec FFRT. Use with C554A scanner