Honeywell DR4500A Truline® 12” Truline®, 4 Channel Circular Chart Recorders
Honeywell’s Truline recorder is a one to four-channel, microprocessor-based, circular chart recorder. Its “one-pen” stylus printhead produces up to four analog traces and prints alphanumeric chart data on a blank heat-sensitive chart. All four traces share the same time line reference which the Truline prints. This eliminates the error caused by pen alignment offsets in conventional pen designs. Since the Truline prints the chart and generates the analog traces at the same time, there is no error due to variations in chart size caused by changes in temperature and humidity. With microprocessor electronics and single printhead, the Truline recorder is easily configured by users to meet a variety of application requirements - from metals to food processing. Models with up to four input channels accept inputs from any one of a variety of sensors or transmitters within the configurable range limits. Also, models are available with one or two independent digital controllers to generate controlled output signals which will operate valves, dampers, heating elements, etc. for process control.
• User Configurable — means that users, using English language prompts, can set and/or alter operating parameters to fit their requirements, including type of input, without recalibration.
• Operator Interface — includes clear, brilliant alphanumeric displays; indicators; deviation bargraph; and keypad for visual and tactile interaction.
• All-Purpose Chart —blank chart eliminates the need for ordering and stocking several types of charts. And, users can design the chart to match specific applications.
• Four Channels — up to four channels that monitor process variables from a variety of sensors reduce panel space requirements.
• “One-pen” Printer — prints configurable alphanumeric chart data including time and trend lines. This automatically compensates for chart width variations caused by changes in the ambient relative humidity.
• Control Output — up to two versatile PID digital controllers let users configure the exact control action needed for their process.
• Time/Date — real-time, clock, dates, time of printing (hour, minutes, date and year) and any operator changes in real time guard against unauthorized chart advancement. There is a 10-year life battery backup.
• Accutune II™ —This standard feature provides a new, truly plug and play tuning algorithm, which will, at the touch of a button or through a digital input, accurately identify and tune any process including those with deadtime and integrating processes. This speeds up and simplifies start-up plus allows re-tuning at any setpoint.
• Fuzzy Logic — This standard feature uses fuzzy logic to suppress process variable overshoot due to SP changes or externally induced process disturbances. It operates independently from AccutuneII™ tuning. It does not change the PID constants, but temporarily modifies the internal controller response to suppress overshoot. This allows more aggressive tuning to co-exist with smooth PV response. It can be enabled or disabled depending on the application or the control criteria.
• Setpoint Ramp — a single set point ramp is user programmable and is easily repeated and activated through the Run/Hold key.
• Setpoint Rate — lets you define a ramp rate applied to any local setpoint change. A separate upscale or downscale rate is configurable.
• Set Point Ramp/Soak Programming — Lets users program and store 18 ramp and 18 soak segments. Run or Hold of program is keyboard or remote switch selectable. Each Control Loop can run one of the 6 profiles using any number of consecutive segments of the program. You can select a recovery mode for power-up.
• Event Messages — up to six event messages can be printed on designated areas of the chart and can be triggered by a specific selectable event
| Digital Indication Accuracy: | 1 digit | ||
| Minimum Input Span: | Range is fully configurable with span limitation of the operating range selected | ||
| Input Impedance: | 4-20 mA dc: 250 ohms 0-10 Vdc: 200K ohms All others: 10 Megohms |
||
| Source Impedance: | RTD: 100 ohms per lead maximum | ||
| Sampling Rate: | Each input sampled 3 times a second (1 or 2 inputs); 3 times in 2 seconds (3 or 4 inputs) | ||
| Input Filter: | Software: Single pole low pass section with selectable time constants (off to 120 seconds) | ||
| Digital Displays: | Vacuum fluorescent, alphanumeric. A six-digit display dedicated to the process variable. Alternate information displayed during configuration mode. An eight-digit display shows key selected operating parameters. Also provides guidance during configuration. |
||
| Indicators: | Channel PV display (CHN 1, 2, 3, or 4) Alarm status (ALM 1, 2) Controller Output (OUT 1 or 2) Remote Set Point (RSP) Temperature unit (F or C) or Engineering units Controller's mode (A or MAN) |
||
| Deviation Bargraph: | 21 segment, color coded deviation bargraph: Green (large) = On Control Green (Small) = Deviation to ± 10% of PV |
||
| Controller Modes of Operation: | Manual Operation Automatic with local set point Automatic with remote set point |
||
| Transmitter Supply Voltage: | 22 to 26 Vdc at input terminals (50 mAdc at 24 Vdc) | ||
| Case/Door: | Molded, foamed-Noryl* with gasketed door to meet NEMA 3 enclosure requirements. Panel gasket available separately. An optional UL and FM approved NEMA4X door is also available. |
||
| Chart: | 12-inch (304.8mm) diameter chart. Plain thermal-sensitive paper. | ||
| Wiring Connections: | Terminals inside the case | ||
| Color: | Case: Black Door (standard): Caribbean Blue, Black or Gray |
||
| Approval Bodies: | U.L. approval depending on model. Consult Model selection Guide for information. FM approved for Class I, Div 2, Groups A, B, C, D areas depending on model. |
||
| Weight: | 13.2 lb. (6 kg) | ||
| Mounting: | Panel or surface mounted. Some adapter kits are available for existing panel cutouts. | ||
| Digital Input: | +20 Vdc source for external dry contact or isolated solid state contacts. Selects one configured input. | ||
| Totalizers: | One or two totalizers on DR45A1, DR45A2, DR45AT and DR45AR Models. Up to four totalizers on DR45AW Model. Eight digit "totals" with multiplier on digital display; 14-digit totalization printout on chart. Grand total can be printed at each major time line. |
||
| Calculations: | Fo calculation available on DR45AR Model. Open channel flow calculations available on DR45AW Model. |
||
| Math Algorithms: | Eight algorithms are available: A + B + C (summer with ratio and bias) √A • B/C (square root multiplier/divider) √A • B • C (square root multiplier) A • B/C (multiplier/divider) A • B • C (multiplier) (A-B) • C (difference multiplier) where: A = Input 1 • ratio A + bias A B = Input 2 • ratio B + bias B C = Input 3 • ratio C + bias C Limit of Ratio = -20 to +20 Limit of Bias = -999 to +9999 High/Low Select between Input 1 and Input 2 Polynomial Equation – Fifth order provides equation |
||
| Miscellaneous: | • UL and FM approved NEMA4X door • Door Lock • Chart Illumination • U.L. Listing, FM Approval, CSA, CE Conformity • Control with Accutune II Tuning Capability • Auxiliary 4-20 mA output • Glass or Acrylic Window • Customer ID Tag • 2 Pulse output counter alarm functions on DR45AW Model • Lead seal provisions |
||
| RS485 Modbus® RTU Communications: | Baud Rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 Protocol: RS485 Modbus RTU Communications Length of Link: 4000 ft (1,219 m) maximum Link Characteristics: Two wire, multidrop |
| Table 1 | Table 2 | Table 3 | Table 4 | Table 5 | Table 6 | Table 7 | Table 8 | Table 9 | Table 10 | Table 11 | Table 12 | Table 13 | Table 14 | Table 15 | Table 16 | Table 17 | Table 18 | Table 19 | Table 20 | Table 21 |
| XXXXXX | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X |
| Table 1 | KEY NUMBER |
| DR45AT | Truline |
| DR45AR | Truline - Relay Expansion |
| DR45AW | Truline - Flow Recorder |
| DR45AH | Truline - HTST |
| DR45AP | Truline - Pasteurization Recorder - Flow |
| DR45AS | Truline - Safety Thermal Limit Recorder |
| Table 2 | Pen One |
| 0 | None |
| 2 | 2 Outputs (Alarm/On-Off Control) |
| 3 | 1 PID Control with Accutune |
| 4 | 1 PID Control/Setpoint Program/Timer |
| 5 | 2 Outputs (Alarm1/Timer) |
| A | 4-20 mA Retransmission Output |
| F | FM Approved Limit Control |
| G | FM Approved Limit Control/Timer Output |
| Table 3 | Pen Two |
| 0 | None |
| 2 | 2 Outputs (Alarm/On-Off Control) |
| 3 | 1 PID Control |
| 4 | 1 PID Control/Setpoint Program/Timer |
| 5 | 2 Outputs (Alarm1/Timer) |
| A | 4-20 mA Retransmission Output |
| F | FM Approved Limit Control |
| G | FM Approved Limit Control/Timer Output |
| Table 4 | Output Type Pen One |
| 0 | None |
| E | Electromechanical Relay |
| S | Solid State Relay |
| T | Open Collector |
| Table 5 | Output Type Pen Two |
| 0 | None |
| E | Electromechanical Relay |
| S | Solid State Relay |
| T | Open Collector |
| Table 6 | Door Options |
| G | Gray Door |
| B | Blue Door |
| H | Gray Door with Key Pad |
| C | Blue Door with Key Pad |
| K | Black Door |
| L | Black Door with Key Pad |
| R | Heavy Duty SST Door |
| 0 | Standard Latch |
| A | Keyed Latch |
| B | Keyed Latch/Chart Plate Seal |
| E | Standard Latch/Chart Plate Seal |
| M | Door Lock |
| K | Door Lock / Chart Plate Seal |
| Table 7 | Instrument Power/Transmitter Power |
| 1 | Universal Power |
| 3 | Universal Power +24VDC Transmitter Power |
| Table 8 | Communications |
| 0 | None |
| C | RS 485 Modbus RTU Communication |
| Table 9 | Product Configuration |
| 0 | Standard Factory Configuration |
| 1 | Configuration for non-standard range settings |
| 2 | Configuration to customer’s specific data |
| Table 10 | PEN 1 Options |
| 0 | No Digital Inputs |
| D | Digital Inputs |
| Table 11 | PEN 1 Options |
| 0 | None |
| Table 12 | PEN 1 Options |
| 0 | No Totalizer Function |
| T | Totalizer |
| Table 13 | PEN 1 Options |
| 0 | Future |
| Table 14 | PEN 2 Options |
| 0 | No Digital Inputs |
| D | Digital Inputs |
| Table 15 | Approvals |
| 0 | No Approvals |
| U | UL Listing |
| C | CSA Certification |
| B | UL and CSA Approval |
| Table 16 | PEN 2 Options |
| 0 | None |
| Table 17 | CERTIFICATES |
| 0 | No Certificates |
| 1 | Certificate of Conformance (F3391) |
| 2 | Certificate of Calibration (F3399) |
| 3 | Certificate of Conformance & Calibration |
| Table 18 | PEN 2 Options |
| 0 | No Totalizer Function |
| T | Totalizer |
| Table 19 | PEN 2 Options |
| 0 | Future |
| Table 20 | DOCUMENTATION |
| 0 | Product Information on CD |
| E | Hard Copy Product Manual |
| Table 21 | DOCUMENTATION |
| 0 | Future |