Jump to Navigation

Current Sensors

The X Series contains current sensors with or without a 10 or 20 Amp relay. An internal 10 Amp relay can be used to activate an external contactor, and currents up to 150 Amps are sensed externally with a Solid or Split current sensing ring.

Other units control and sense up to 20 Amp...

The X Series contains current sensors with or without a 10 or 20 Amp relay. An internal 10 Amp relay can be used to activate an external contactor, and currents up to 150 Amps are sensed externally with a Solid or Split current sensing ring.

Other units control and sense up to 20 Amp...

Adjustable Trip Point (H308... H908)

Hx08 Series and H701 current switches offer high performance, with a wide array of amperage range options. These products can accurately detect belt loss, coupling shear, or other mechanical failure on loads from 1/5 to 100HP.
• Detecting belt loss, coupling shear, and mechanical failure...

Adjustable Trip Point (H735... H958)

The Hawkeye Relay Combination Series is the ideal solution for the automation installer. These units combine a current switch and relay into a single package, reducing the space required for total control of fans and pumps. The current switch and relay operate independently of one another. These...

Auto Calibration (H904... H934)

Hawkeye 904/934 microprocessor-based current status switches provide a unique solution for accurately monitoring status of motors controlled by variable frequency drives. The H904/934 store the sensed amperage values for normal operation at various frequency ranges in nonvolatile memory. This...

CSP/CSS

All of these sensors have a solid-state output with an adjustable or fixed trip point (setpoint). These current switches should be used in applications in which a “Go/No Go” current switch is required. The current switches can be used to monitor devices with a maximum continuous operating...

CTP/CTS

Depending on model selected the current is converted into a linear and proportional output signal of 0-5 Vdc, 0-10 Vdc or 4-20 mA, which can be monitored by a building management controller. These current sensors should be used in load trending (current monitoring) type applications. The split...

Field Mount Status Relay (H120, H120NC)

The H120/H120NC offer a fixed current switch and SPST relay in a single externally mounted housing. Combining the current sensor and relay in one easy-to-install package eliminates the need to fit multiple devices into small electrical enclosures and simplifies the installation. Eliminate the...

Fixed Trip Point (H300... H900)

Hawkeye x00 go/no go current switches provide a cost-effective solution for monitoring status on unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern. Veris has applied new technology to the H300, H600, and H800 models to achieve impressive...

R310A

The R310A Series Current Sensing Switch detects alternating current (AC) flow in a single circuit without being connected to that circuit. It may be used in any application where current detection is required. The R310A replaces the R10A used with Johnson Controls/PENN time delay oil failure...

Subscribe to Current Sensors


Main menu 2

about seo